U-Line E5 in the error log: thermistor 1 shorted
On U-Line's clear ice and craft ice models, E5 in the service error log means thermistor 1 is shorted.
Mon–Sat, 8am–8pm
- Temperature sensors
- Ice maker control and sensor repair
- Source: U-Line
Book a visit
Three short steps, about a minute.
or call (844) 773-0701
Loading appointment form…
The appointment form couldn’t load. Please try again.
What E5
actually means.
On U-Line's clear ice and craft ice models, E5 in the service error log means thermistor 1 is shorted. A shorted sensor gives the control a false temperature, so it can misjudge the bin or the cycle it is managing.
U-Line ice maker display
What to do when E5 shows on the ice makerKind of codeTemperature sensors
The control lost track of how cold the ice mold or the ice compartment is, because a thermistor reads nonsense or its wire lost contact. Without that reading the ice maker cannot tell when a batch is frozen, so it stops or harvests at the wrong time. Frost packed around the sensor and a loose plug are checked before the sensor itself is changed.
Usually leads toIce maker control and sensor repair
The control board, the thermistors, the bin sensor and the wiring that decide when an ice maker fills, freezes and stops, tested and repaired when a light flashes, a code shows, a breaker trips or the ice never stops coming.
Shows up asIce Maker Making Too Much Ice
The ice maker making too much ice overfills the bin, pushes cubes into the chute, jams the door ice compartment or keeps the freezer drawer from closing.
MakeU-Line
U-Line undercounter ice maker service, including cleaning, descaling and drain repair.
SourceU-Line User Guide & Service Manual, UHCL115 15-inch clear ice model (u-line.com PDF)
U-Line 15-inch clear ice (HCL, OCL, ACP) and craft ice (RCC) models. U-Line says all errors are logged in memory, but only the door error shows on the display with a tone; the others are read from the error log in service mode.
Before you book,
in this order.
Each step comes from U-Line's own guidance for E5 on its ice makers. Follow it to the end: the last card says whether this is a visit.
Write down E5 and the model and serial numbers from the plate inside the unit.
Watch whether the bin overfills or stays low; that tells the technician how the bad reading is affecting the unit.
Book a visit to have the thermistor and its harness tested.
Still there?
It usually turns into ice maker control and sensor repair. Book with the code and the model number.
What not to do
E5 is not the same as E1. E1 means the sensor circuit is open, while E5 means it is shorted.
What you may
notice with it.
The ice maker problems E5 tends to arrive with. Answer these at the ice maker before anyone is booked.
All problemsWhere E5 usually leads
Ice maker control and sensor repair.
U-Line
ice makers.
U-Line undercounter ice maker service, including cleaning, descaling and drain repair.
U-Line ice maker repairMore U-Line codes
Temperature sensors on other makes
In U-Line's own words
E5: Thermistor 1 shorted.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. U-Line 15-inch clear ice (HCL, OCL, ACP) and craft ice (RCC) models. U-Line says all errors are logged in memory, but only the door error shows on the display with a tone; the others are read from the error log in service mode.
U-Line E5 ice maker repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about E5.
Can I clear E5 myself?
Is E5 on a U-Line serious?
Can moisture cause E5 on an outdoor U-Line ice maker?
Does replacing a U-Line thermistor clear E5 from the log?
Back to your everyday
Still showing E5?
Book with the code or the blink pattern written exactly as the ice maker shows it, the full model number, and whether there is any water on the floor — when there is a code, that is where the diagnosis starts.